  • Product Overview

    Activin E is a key member of the transforming growth factor-β (TGF-β) superfamily. Primarily encoded by the INHBE gene and highly expressed in the liver, it is a dimeric protein (≈23 kDa) formed by two βE subunits linked via disulfide bonds. This kit is specifically designed for the accurate quantitation of mature human Activin E Dimer from cell culture supernates, serum and plasma. The standard is a recombinant mature Activin E dimer protein, and the antibodies specifically recognize the mature Activin E dimer. Our ELISA Kit provides several benefits:

    1. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    2. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    3. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    Activin E Dimer
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    60 pg/mL
    Assay Time
    2.75 hr
    Sample volume
    50 μL
    Range
    78.125 pg/mL-5000 pg/mL
    Sample Type
    For the quantitative determination human Activin E Dimer in serum, plasma and cell supernatant.

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for quantitative detection of natural and recombinant mature human Activin E dimer (not monomeric INHBE) in serum, plasma and cell culture supernates.

    It is for research use only.

  • Workflow

    Activin E Workflow

  • Storage

    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CEA247-C01
    Pre-coated Anti-Activin E Dimer Antibody Microplate
    1 plate
    CEA247-C02
    Human Activin E Dimer Standard
    1.8 μg×2
    CEA247-C03
    Biotin-Anti-Activin E Dimer Antibody Con. Solution
    100 μL
    CEA247-C04
    Biotin-Antibody Dilution Buffer
    8 mL
    CEA247-C05
    Streptavidin-HRP Con. Solution
    500 μL
    CEA247-C06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CEA247-C07
    20×Washing Buffer
    50 mL
    CEA247-C08
    Sample Dilution Buffer
    15 mL×2
    CEA247-C09
    Substrate Solution
    12 mL
    CEA247-C10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     Activin E TYPICAL DATA

    For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of Human Activin E is less than 60 pg/mL.

Validation
  • Sample Values

    Healthy and High BMI donor serum samples were evaluated for the concentrations of human Activin E in assay. The sample detection rate was 100%. Mean of healthy donor is 12.78 ng/mL and mean of high BMI donor is 28.13 ng/mL.

     Activin E SAMPLE VALUES
  • Methodology Comparison

    Comparison of LC-MS/MS and ELISA for the quantification of Activin E in human serum: Excellent correlation and high result consistency between the two detection methods.

     Activin E METHODOLOGY COMPARISON
  • Cross Verification

    Activin E (Oligomeric/non-dimeric forms) and Activin C were detected in this assay. The cross-reactivity rate (%) is shown in the following Table.

     Activin E CROSS VERIFICATION
  • Intra-Assay Statistics

    Ten replicates of each of three samples containing different Activin E concentrations were tested in one assay. Acceptable criteria: CV<10%.

     Activin E INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples containing different concentrations of Activin E were tested in independent assays. Acceptable criteria: CV<15%.

     Activin E INTER-ASSAY STATISTICS
  • Recovery

    Recombinant Activin E was spiked into three diluted human serum samples, and then analyzed. The average recovery of Activin E for serum samples is 91.1%.

     Activin E RECOVERY

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521

[North America]: 1 Innovation Way, Newark, DE 19711, USA
[Switzerland]: ACRObiosystems AG, c/o Zug Dammstrasse Centre AG, Dammstrasse 19, 6300 Zug Switzerland