My Cart

resDetect™ Human Interleukin-21 (IL-21) ELISA Kit (Residue Testing)

Customer Reviews
Cat. No. / Size
Price
Qty
CRS-A010-96tests
$450.00
ETA of in-stock products:2 business days
Sub-Total$ 0

Product Details

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    IL-21
    Format
    96T (8×12 strips)
    Reactivity
    Human
    Regulatory Status
    RUO
    Sensitivity
    < 1.56 pg/mL
    Standard Curve Range
    1.56 pg/mL-100 pg/mL
    Assay Time
    2 hr 50 min
    Suitable Sample Type
    For the quantitative determination of human IL-21 in Cell Culture Supernatants, Plasma, Serum.
    Sample volume
    100 μL

  • Product Overview

    Human Interleukin-21 (IL-21) ELISA Kit (Residue Testing) is based on the ELISA sandwich method and is used to detect and quantitatively determine GMP human IL-21 in cell culture supernatants, serum, and plasma. The kit contains GMP human IL-21 (ACROBiosystems, cat#GMP-L21H25) to ensure accurate assay results. It is designed to provide a reliable solution for CAR-T product quality assessment during drug development and CMC quality control stages. Additionally, it can be used as a universal detection tool for the quantitative determination of human IL-21.

  • Reconstitution

    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

  • Storage

    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CRS010-C01
    Pre-coated Anti-IL-21 Antibody Microplate
    1 plate (8×12 strips)
    CRS010-C02
    Human IL-21 Standard
    20 μg
    CRS010-C03
    Biotin-Anti-IL-21 Antibody
    50 μL
    CRS010-C04
    Streptavidin-HRP
    50 μL
    CRS010-C05
    10xWashing Buffer
    50 mL
    CRS010-C06
    2xDilution Buffer
    50 mL
    CRS010-C07
    Substrate Solution
    12 mL
    CRS010-C08
    Stop Solution
    7 mL

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     IL-21 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
  • Dilution Linearity

    To assess the linearity of the assay, samples spiked with high concentrations of human IL-21 were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.

     IL-21 DILUTION LINEARITY
  • Intra-Assay Statistics

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision, Intra-Assay Precision CV<10%.

     IL-21 INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples of known concentration were tested in three separate assays to assess inter-assay precision, Inter-Assay Precision CV<10%.

     IL-21 INTER-ASSAY STATISTICS
  • Recovery

    Three parts of blank serum were added with different concentrations of human IL-21, and the serum without human IL-21 was used as background to calculate the recovery rate. The range of the recovery rate is 80.6-118.1%, and the average recovery is 94.0%.

     IL-21 RECOVERY

Customer Reviews
Writing Reviews

Recent Advances

 
Drug Development Progress
  • English Name:

    Interleukin-21

  • Category:

  • Approved Drugs:

    0 Details

  • Drugs in Clinical Trials:

    4 Details

  • Highest Development Stage:

    Phase 2 Clinical

Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521

[North America]: 1 Innovation Way, Newark, DE 19711, USA
[Switzerland]: ACRObiosystems AG, c/o Zug Dammstrasse Centre AG, Dammstrasse 19, 6300 Zug Switzerland