resDetect™ Human TPO ELISA Kit (Residue Testing)

Customer Reviews
Cat. No. / Size
Price
Qty
RES-A034-96tests
$510.00
ETA of in-stock products:2 business days
Sub-Total$ 0

Product Details

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    TPO
    Format
    96T (8×12 strips)
    Reactivity
    Human
    Regulatory Status
    RUO
    Sensitivity
    <12.5 pg/mL
    Standard Curve Range
    12.5 pg/mL-400 pg/mL
    Assay Time
    3 hr 20 min
    Suitable Sample Type
    For the detection and quantitative determination of TPO in human serum and cell culture supernates.
    Sample volume
    100 μL

  • Product Overview

    Human TPO ELISA Kit (Residue Testing) is based on the ELISA sandwich method and is used to detect and quantitatively determine GMP Human TPO residues in cell culture supernatants, serum, and plasma. The kit contains GMP human TPO (ACROBiosystems, cat# GMP-THNH25) to ensure accurate assay results and is designed to provide a reliable solution for CAR-T product quality assessment during drug development and CMC quality control stages. It can also be used as a universal detection tool for the quantitative determination of Human TPO.

  • Reconstitution

    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

  • Storage

    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    RES034-C01
    Pre-coated Anti-TPO Antibody Microplate
    1 plate (8×12 strips)
    RES034-C02
    Human TPO Standard
    20 μg
    RES034-C03
    Biotin-Anti-TPO Antibody
    20 μg
    RES034-C04
    Streptavidin-HRP
    50 μL
    RES034-C05
    10×Washing Buffer
    50 mL
    RES034-C06
    2×Dilution Buffer
    50 mL
    RES034-C07
    Substrate Solution
    12 mL
    RES034-C08
    Stop Solution
    7 mL

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     TPO TYPICAL DATA

    For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
  • Dilution Linearity

    To assess the linearity of the assay, samples spiked with high concentrations of TPO were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.

     TPO DILUTION LINEARITY
  • Intra-Assay Statistics

    Three samples of known concentration were tested ten times on one plate to assess intra-assay precision.

     TPO INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples of known concentration were tested in three separate assays to assess inter-assay precision.

     TPO INTER-ASSAY STATISTICS
  • Recovery

    Five parts of blank T cell culture supernatant were added with different concentrations of human TPO, and the T cell culture supernatant without human TPO was used as background to calculate the recovery rate. The range of the recovery rate is 94.7-108.9%, and the average recovery is 102.1%.

     TPO RECOVERY

Customer Reviews
Writing Reviews

Recent Advances

 
Contact Us
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews
Contact Us

[North America]: +1 800-810-0816
[Switzerland]: +41 800 040 012
[Asia & Pacific]: +86 400-682-2521

[North America]: 1 Innovation Way, Newark, DE 19711, USA
[Switzerland]: ACRObiosystems AG, c/o Zug Dammstrasse Centre AG, Dammstrasse 19, 6300 Zug Switzerland