选择语言

R-PE Antibody Labeling Kit

用户评价
货号-规格
价格
Qty.
ALK-A001-100ug
¥2990.00
ALK-A001-500ug
¥6000.00
ALK-A001-1mg
¥7500.00
合计0件 产品金额¥ 0

产品详情

  • 应用说明(Application)

    R-PE Antibody Labeling Kit uses a simple and quick process for PE conjugation of antibody. The conjugated antibody can be used straight away without further purification step and antibody loss.

    It is for research use only.

  • 背景(Background)

    R-Phycoerythrin (PE) is an orange fluorescent protein which has an excitation wavelength of 488 nm/561 nm and an emission wavelength of 575nm. R-PE Antibody Labeling Kit provides a rapid and simple method to covalently link via the interchain disulfide bonds of the antibody.

  • 原理(Assay Principles)

    PE Antibody Labeling Kit provides a rapid and simple method for achieving covalently coupling of PE and antibody molecules. The interchain disulfide bonds of the antibody can be modified to generate active cysteine residues, which are then conjugated with the preactivated PE to obtain the PE-antibody conjugate.

    - Assay Principles

  • 组分(Materials Provided)

    ID
    Components
    Size
    ALK01-C01
    Modifier reagent
    1 vial
    ALK01-C02
    Activated PE
    1 vial
    ALK01-C03
    Quencher reagent
    1 vial
  • 存储(Storage)

    1. Unopened kit should be stored at -20℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

  • 质量管理控制体系(QMS)

    1. 质量管理体系(ISO, GMP)
    2. 质量优势
    3. 质控流程

产品展示

  • 流式数据 -FACS Data

    Please refer to DS document for the assay protocol.

     - FACS

    2.5e5 RC222 cells (anti-CD19 CAR-293 cells, G4S linker is used in CARs) and jurkat cells (with expression of the CD3 antigen) were stained with 100μL of 1μg/mL PE labeled antibody, and analyzed with FACS.
    The results show ALK-A001 can be used for different antibodies conjugation.

  • 活性(Bioactivity)-FACS

    Please refer to DS document for the assay protocol.

     - FACS

    Binding signal of products prepared by different size of PE antibody labeling Kit (ALK-A001). The result shows very high consistency (QC tested).

  •  - FACS

    The binding signal of PE labeled anti-FMC63 antibody using ALK-A001 Kit was higher than the other competitor kit (Routinely tested).

  •  - FACS

    The binding signal of PE labeled anti-CD3 antibody using ALK-A001 Kit was higher than the other competitor kit (Routinely tested).

用户评价
发表评论

前沿进展

 
联系我们
项目合作
查看更多项目
  • 产品SKU
  • 产品详情
  • 产品展示
  • 用户评价