resDetect™ Human DLL4 ELISA Kit (Residue Testing)

用户评价
货号-规格
价格
Qty.
RES-A052-96tests
¥2940.00
合计0件 产品金额¥ 0

产品详情

  • 产品参数(Product Specifications)

    Assay Type
    Sandwich-ELISA
    Analyte
    DLL4
    Format
    96T(8×12 strips)
    Reactivity
    Human
    Regulatory Status
    RUO
    Sensitivity
    < 18.75 pg/mL
    Standard Curve Range
    18.75 pg/mL-1200 pg/mL
    Assay Time
    3 hr 20 min
    Suitable Sample Type
    For the quantitative determination of human DLL4 in Cell Culture Supernatants, Plasma, Serum.
    Sample volume
    100 uL

  • 产品概述(Product Overview)

    resDetect™ Human DLL4 ELISA Kit (Residue Testing) is based on the ELISA indirect method and is used to detect and quantitatively determine GMP human DLL4 residues in cell culture supernatants, serum, and plasma. The kit contains GMP Human DLL4 Protein, Fc Tag (ACROBiosystems, cat# GMP-DL4H28) to ensure accurate assay results and is designed to provide a reliable solution for CAR-T product quality assessment during drug development and CMC quality control stages. It can also be used as a universal detection tool for the quantitative determination of human DLL4.

  • 重构方法(Reconstitution)

    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

  • 存储(Storage)

    Unopened kit should be stored at 2°C -8°C upon receiving.

    Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • 组分(Materials Provided)

    ID
    Components
    Size
    RES052-C01
    Pre-coated Anti-DLL4 Antibody Microplate
    1 plate(8×12 strips)
    RES052-C02
    Human Fc Tag DLL4 Standard
    20 μg
    RES052-C03
    Biotin-Anti-DLL4 Antibody
    150 μL
    RES052-C04
    Streptavidin-HRP
    50 μL
    RES052-C05
    10xWashing Buffer
    50 mL
    RES052-C06
    2xDilution Buffer
    50 mL
    RES052-C07
    Substrate Solution
    12 mL
    RES052-C08
    Stop Solution
    7 mL

  • 原理(Assay Principles)

    This assay kit employs a standard sandwich-ELISA format, providing a rapid detection of Human Fc Tag DLL4. The kit consists of Pre-coated Anti-DLL4 Antibody Microplate and Human Fc Tag DLL4 Standard and Biotin-Anti-DLL4 Antibody and Streptavidin-HRP and buffers.

    Your experiment will include 6 simple steps:

    a) Bring all reagents to room temperature(20℃-25℃) before use.

    b) Add your sample to the plate and take the Human Fc Tag DLL4 Standard. The samples and standard are diluted by Dilution Buffer.

    c) Wash the plate and add the Biotin-Anti-DLL4 Antibody diluted by Dilution Buffer to the plate.

    d) Wash the plate and add the Streptavidin-HRP diluted by Dilution Buffer to the plate.

    e) Wash the plate and add TMB.

    f) Stop the substrate reaction by adding diluted acid. Absorbance (OD) is calculated by the absorbance at 450 nm minus the absorbance at 630 nm to remove background disturbance before statistical analysis. The OD Value reflects the amount of bound protein.

  • 质量管理控制体系(QMS)

    1. 质量管理体系(ISO, GMP)
    2. 质量优势
    3. 质控流程

产品展示

  • 典型数据-Typical Data

    Please refer to DS document for the assay protocol.

     DLL4 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

验证
  • 稀释线性(Dilution Linearity)

    To assess the linearity of the assay, samples spiked with high concentrations of human Fc Tag DLL4 were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.

     DLL4 DILUTION LINEARITY
  • 批内差异(Intra-Assay Statistics)

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision, Intra-Assay Precision CV<10%.

     DLL4 INTRA-ASSAY STATISTICS
  • 批间差异(Inter-Assay Statistics)

    Three samples of known concentration were tested in three separate assays to assess inter-assay precision, Inter-Assay Precision CV<10%.

     DLL4 INTER-ASSAY STATISTICS
  • 回收率(Recovery)

    Three parts of blank serum were added with different concentrations of human Fc Tag DLL4, and the serum without human Fc Tag DLL4 was used as background to calculate the recovery rate. The range of the recovery rate is 83.7-116.5%, and the average recovery is 98.6%.

     DLL4 RECOVERY

用户评价
发表评论

背景介绍

Delta-like protein 4 (DLL4) is also known as Drosophila Delta homolog 4 (Delta4), which contains one DSL domain and eight EGF-like domains. DLL4 is expressed in vascular endothelium. DLL4 is involved in the Notch signaling pathway as Notch ligand, which can activates NOTCH1 and NOTCH4. DLL4 is involved in angiogenesis and negatively regulates endothelial cell proliferation and migration and angiogenic sprouting. DLL4 can bind to Notch-1 and Notch-4.

前沿进展

 
药物研发进展
  • 英文全称:

    Delta-like protein 4

  • 中文全称:

    δ样蛋白-4

  • 种类:

  • 上市药物数量:

    0 详情

  • 临床药物数量:

    3 详情

  • 最高研发阶段:

    临床三期

联系我们
项目合作
查看更多项目
  • 产品SKU
  • 产品详情
  • 产品展示
  • 用户评价
  • 背景介绍