产品详情
产品参数(Product Specifications)
Assay TypeSandwich-ELISAAnalyteSCFFormat96T(8×12 strips)ReactivityHumanRegulatory StatusRUOSensitivity<15.625 pg/mLStandard Curve Range15.625 pg/mL-1000 pg/mLAssay Time2 hr 50 minSuitable Sample TypeFor the detection and quantitative determination of GMP human SCF in human serum and cell culture supernates.Sample volume100 uL产品概述(Product Overview)
resDetect™ Human SCF ELISA Kit (Residue Testing) is based on the ELISA sandwich method and is used to detect and quantitatively determine GMP human SCF residues in cell culture supernatants, serum, and plasma. It contains GMP human SCF (ACROBiosystems, cat# GMP-SCFH25) to ensure accurate assay results and is designed to provide a reliable solution for CAR-T product quality assessment during drug development and CMC quality control stages. It can also be used as a universal detection tool for the quantitative determination of human SCF.
重构方法(Reconstitution)
Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
存储(Storage)
2-8℃
组分(Materials Provided)
IDComponentsSizeRES006-C01Pre-coated Anti-SCF Antibody Microplate1 plate(8×12 strips)RES006-C02Human SCF Standard20 μgRES006-C03Biotin-Anti-SCF Antibody20 μgRES006-C04Streptavidin-HRP50 μLRES006-C0510×Washing Buffer50 mLRES006-C062×Dilution Buffer50 mLRES006-C07Substrate Solution12 mLRES006-C08Stop Solution7 mL原理(Assay Principles)
This assay kit employs a standard sandwich-ELISA format, providing a rapid detection of Human SCF. The kit consists of Pre-coated Anti-SCF Antibody Microplate and Human SCF Standard and Biotin-Anti-SCF Antibody and Streptavidin-HRP and buffers.
Your experiment will include 6 simple steps:
a) Bring all reagents to room temperature(20℃-25℃) before use.
b) Add your sample to the plate and take the Human SCF as standard. The samples and standard are diluted by Dilution Buffer.
c) Wash the plate and add the Biotin-Anti-SCF Antibody diluted by Dilution Buffer to the plate.
d) Wash the plate and add the Streptavidin-HRP diluted by Dilution Buffer to the plate.
e) Wash the plate and add TMB.
f) Stop the substrate reaction by adding diluted acid. Absorbance (OD) is calculated by the absorbance at 450 nm minus the absorbance at 630 nm to remove background disturbance before statistical analysis. The OD Value reflects the amount of bound protein.
质量管理控制体系(QMS)
产品展示
典型数据-Typical Data
Please refer to DS document for the assay protocol.
For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.
稀释线性(Dilution Linearity)
To assess the linearity of the assay, samples spiked with high concentrations of human SCF were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.
批内差异(Intra-Assay Statistics)
Three samples of known concentration were tested ten times on one plate to assess intra-assay precision.
批间差异(Inter-Assay Statistics)
Three samples of known concentration were tested in three separate assays to assess inter-assay precision.
回收率(Recovery)
Five parts of blank T cell culture supernatant were added with different concentrations of human SCF, and the T cell culture supernatant without human SCF was used as background to calculate the recovery rate. The range of the recovery rate is 90.9-101.3%, and the average recovery is 95.3%.